4.9 Hydrostatic test. All tubing shall be subjected to the minimum hydrostatic pressure specified (see 6.2).
The test shall be performed on tubing lengths up to 12 feet. The outside diameter of each test length shall be gauged
in the same location before and after application of the specified pressure. Failure of the tubing to meet the
requirements of 3.7 shall be cause for rejection of the lot.
4.10 Marking. The marking requirements of 3.8 shall be verified by visual inspection.
4.11 Workmanship. All tubing shall be visually examined for compliance with surface conditions and
workmanship requirements.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the contract or
order (see 6.2). When packaging of materiel is to be performed by DoD or in-house contractor personnel, these
personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging
requirements are maintained by the Inventory Control Point s packaging activities within the Military Service or
Defense Agency, or within the military service s system commands. Packaging data retrieval is available from the
managing Military Department s or Defense Agency s automated packaging files, CD-ROM products, or by
contacting the responsible packaging activity.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)
6.1 Intended use. The seamless alloy steel tubing covered by this specification is manufactured into primer
tubes subjected by explosive charges to high internal gas pressures of short duration. Since the primer tubes are
manufactured for use in U. S. Navy gun ammunition, there is no commercial application.
6.2 Acquisition requirements. Acquisition documents should specify the following:
a.
Title, number, and date of this specification.
b.
Grade of material (see 1.2).
c.
Dimensions (see 3.5).
d.
Quantity and lengths.
e.
Tolerances, if other than specified in 3.6.
f.
g.
Conformance inspection levels, if other than specified in 4.1.
h.
i.
Preservation, if other than specified in 6.4.1.